Photographs have been adapted for the website; dimensions may vary.
Thermal and Water-Vapour Resistance Tester – Sweating Guarded Hotplate (RET-01A)
Termal ve Su Buharı Direnci Test Cihazı – Terleyen Sıcak Plaka (RET-01A)
Measures thermal resistance (Rct) and water-vapour resistance (Ret) of textiles and textile-like flat materials by the ISO 11092 sweating guarded-hotplate method. 200 × 200 mm porous heated measuring plate, independent active guard and bottom thermal guard; integrated climate chamber (15–55 °C, 30–70% RH), horizontal airflow. Rct 0.002–2.000 m²·K/W, Ret 0–1000 m²·Pa/W; Windows-based software with automatic steady-state detection.
Model technical data
- Method: ISO 11092 sweating guarded-hotplate.
- Measured quantities: Rct thermal resistance; Ret water-vapour resistance.
- Rct range: 0.002–2.000 m²·K/W; Ret range: 0–1000 m²·Pa/W.
- Measuring area: 200 × 200 mm square plate; specimen min. 300 × 300 mm, thickness 0–50 mm (optional 70 mm).
- Climate chamber: 15–55 °C, 30–70% RH; horizontal, uniform airflow.
- Channels: plate/guard/bottom guard temperature, air T/RH/speed, real power.
- Control and report: Windows-based software, independent process control; automatic steady-state detection, Turkish/English report.
Physical specifications and utilities
| Electrical supply | Approx. 220–240 V AC, 50/60 Hz, single phase; build-dependent. |
|---|---|
| Power / connected load | Approx. 3500–6000 W connected load for preliminary planning. |
| Overall instrument dimensions | Approx. 1200 × 1000 × 1800 mm (W × D × H). |
| Instrument weight | Approx. 350–550 kg net. |
| Gross / shipping weight | Approx. 410–712.5 kg gross; estimated packing allowance. |
| Lab requirements | Ventilated installation; purified water and drain for humidification options. Separate conditioning plant depends on order scope. |
Dimension order and approximate values are stated in each row. Packaging data are separate from instrument dimensions and net mass. Approx. rows are preliminary engineering estimates based on comparable equipment and function/capacity; they are not verified manufacturing measurements or standard requirements. Installation and shipment are finalised against the approved drawing and nameplate. Estimate scope: base product / one unit; external computer, bench and auxiliary plant excluded.
Specifications, dimensions, and power requirements are approximate and subject to change without prior notice for continuous design improvements.
Product technical specifications and images may vary according to manufacturing conditions and applicable standards.
Test and configuration
- Measured output / function
- Thermal resistance Rct and water vapour resistance Ret
- Parameters selected for the method
- Plate temperature, climate, air speed and specimen placement
- Verification points
- Temperature, heating power, air speed and bare-plate correction
Listed methods are application references. Suitability is established by assessing the selected hardware, current method and calibration together.
Test parameters for the reviewed method
Values belong to the stated source edition. Test recipe, fixture and delivered instrument configuration are selected together.
ISO 11092 (earlier edition) · 5.1-5.3
- Effective measuring-plate area at least 0.04 m²; plate temperature stability ±0.1 K; heating-power measurement ±2%.
- At the specified measuring point, air speed 1 m/s with test drift no greater than ±0.05 m/s; relative-humidity drift no greater than ±3% RH.
Control and recording specification
The following are method-specific software/recording requirements; delivered software modules are defined by the order scope.
- Method code and edition, specimen ID, operator and selected test parameters are linked to the record.
- The calculation and endpoint are defined by the selected method edition; instrument signals and operator assessments are kept distinct.
- Raw measurements, units, valid/invalid test flags and the reported result remain traceable.
- Calculations are checked against known inputs and an independent calculation; sensor channels are checked against calibration values.
Test standards
- ISO 11092 Textiles — Physiological effects — Measurement of thermal and water-vapour resistance under steady-state conditions (sweating guarded-hotplate test)
- ASTM F1868 Standard Test Method for Thermal Resistance, Evaporative Resistance, and Total Heat Loss Measurements of Clothing Materials Using a Sweating Hot Plate
- ASTM D1518 Standard Test Method for Thermal Resistance of Batting Systems Using a Hot Plate
- GB/T 11048 Textiles — Physiological effects — Measurement of thermal and water-vapour resistance under steady-state conditions (sweating guarded-hotplate test)
Prices start from €18. Request the technical specification and a quotation for this instrument.
Request a quoteCall usPDF catalogueMore in this category

Fabric Tensile Strength Tester

Crockmeter — Colour Fastness to Rubbing

Rotary Crockmeter

Elmendorf Tear Resistance Tester
Other instruments in this group
- TXL-KMS-001Fabric Tensile Strength Tester
- TXL-KMS-002Crockmeter — Colour Fastness to Rubbing
- TXL-KMS-036Steaming Cylinder
- TXL-KMS-037Sewability Tester
- TXL-KMS-038Fabric Stiffness Tester — Manual (Fixed Angle)
- TXL-KMS-0393D-MMD Fabric Liquid Moisture Transmission Measurement Device
- TXL-KMS-045Stretch and Recovery Tester
- TXL-KMS-046Wyzenbeek Abrasion Tester (WY-4, 4 Stations)
- TXL-KMS-048Hydraulic Bursting Strength Tester (K012H)
- TXL-KMS-049Fusible Interlining Bond Strength Tester (TL-FIT 500N)
- TXL-KMS-050Random Tumble Pilling Tester
- TXL-KMS-051Pneumatic Bursting Strength Tester (K012-P)