Photographs have been adapted for the website; dimensions may vary.
Sewability Tester
Dikilebilirlik Test Cihazı
Tests fabric sewability independently of sewing conditions or operator skill. It measures needle penetration force; the value is read in cN and can be converted to other units. USB data output is standard; PC software and printer are optional.
Model technical data
- Tests fabric sewability independently of sewing conditions or operator skill.
- Needle penetration force measurement is performed.
- The value is read in cN and can be converted to different units of measurement.
- USB data output is standard; PC software and printer are optional.
Physical specifications and utilities
| Electrical supply | Approx. 220–240 V AC, 50/60 Hz, single phase; build-dependent. |
|---|---|
| Power / connected load | Approx. 100–400 W connected load for preliminary planning. |
| Overall instrument dimensions | Approx. 700 × 450 × 600 mm (W × D × H). |
| Instrument weight | Approx. 25–50 kg net. |
| Gross / shipping weight | Approx. 37.5–72.5 kg gross; estimated packing allowance. |
| Interfaces | USB data output is standard; PC software and printer are optional. |
| Lab requirements | Level, stable working surface; specimen conditioning follows the selected method. |
Dimension order and approximate values are stated in each row. Packaging data are separate from instrument dimensions and net mass. Approx. rows are preliminary engineering estimates based on comparable equipment and function/capacity; they are not verified manufacturing measurements or standard requirements. Installation and shipment are finalised against the approved drawing and nameplate. Estimate scope: base product / one unit; external computer, bench and auxiliary plant excluded.
Specifications, dimensions, and power requirements are approximate and subject to change without prior notice for continuous design improvements.
Product technical specifications and images may vary according to manufacturing conditions and applicable standards.
Test and configuration
- Measured output / function
- Needle penetration force and sewability
- Parameters selected for the method
- Needle type, specimen structure, speed and cycles
- Verification points
- Force sensor, needle and travel speed
Listed methods are application references. Suitability is established by assessing the selected hardware, current method and calibration together.
Control and recording specification
The following are method-specific software/recording requirements; delivered software modules are defined by the order scope.
- Method code and edition, specimen ID, operator and selected test parameters are linked to the record.
- The calculation and endpoint are defined by the selected method edition; instrument signals and operator assessments are kept distinct.
- Raw measurements, units, valid/invalid test flags and the reported result remain traceable.
- Calculations are checked against known inputs and an independent calculation; sensor channels are checked against calibration values.
Prices start from €18. Request the technical specification and a quotation for this instrument.
Request a quoteCall usPDF catalogue