Washing Fastness Tester
Yıkama Haslığı Test Cihazı
Rotary tumbling washing fastness. ISO 105-C / AATCC.
Model technical data
- Number of test vessels: 6 standard; 8/12/16/20/24 tube options available.
- Test vessel volume: 550 ml.
- Rotation speed: 40 ± 2 rpm.
- Operating temperature: ambient – 98 °C.
- Temperature accuracy: ± 1 °C.
- Programmable memory-based control system with 3.5" touch screen.
- Colour fastness to washing, dry cleaning and chlorinated water.
Physical specifications and utilities
| Electrical supply | Approx. 220–240 V AC, 50/60 Hz, single phase; build-dependent. |
|---|---|
| Power / connected load | Approx. 2500–5500 W connected load for preliminary planning. |
| Overall instrument dimensions | Approx. 850 × 800 × 1050 mm (W × D × H). |
| Instrument weight | Approx. 90–150 kg net. |
| Gross / shipping weight | Approx. 124–212.5 kg gross; estimated packing allowance. |
| Lab requirements | Water supply and drain; hot water, water quality and plumbing capacity depend on order configuration. |
Dimension order and approximate values are stated in each row. Packaging data are separate from instrument dimensions and net mass. Approx. rows are preliminary engineering estimates based on comparable equipment and function/capacity; they are not verified manufacturing measurements or standard requirements. Installation and shipment are finalised against the approved drawing and nameplate. Estimate scope: base product / one unit; external computer, bench and auxiliary plant excluded.
Specifications, dimensions, and power requirements are approximate and subject to change without prior notice for continuous design improvements.
Product technical specifications and images may vary according to manufacturing conditions and applicable standards.
Test and configuration
- Measured output / function
- Colour change and staining of adjacent fabric
- Parameters selected for the method
- Vessel volume, temperature, time, detergent and balls
- Verification points
- Bath temperature, rotational speed and timer
Listed methods are application references. Suitability is established by assessing the selected hardware, current method and calibration together.
Test parameters for the reviewed method
Values belong to the stated source edition. Test recipe, fixture and delivered instrument configuration are selected together.
ISO 105-C06 (earlier edition) · 4.1-4.2
- ISO vessel arrangement: 550 ± 50 ml; diameter 75 ± 5 mm and height 125 ± 10 mm; rotation 40 ± 2 r/min; solution temperature within ±2 °C of the selected value.
ISO 105-C08:2010 · 5.1-5.2
- Wash vessel 550 ± 50 mL; diameter 75 ± 5 mm, height 125 ± 10 mm; rotation 40 ± 2 r/min. Solution within ±2 °C of the selected test temperature; weighing accuracy 0.01 g.
TS EN ISO 105-C09:2003 · 5.1-5.3
- Recipe: vessel rotation 40 ± 2 r/min and solution-temperature deviation no greater than ±2 °C. Preparation mixer at least 1000 r/min and balance precision ±0.01 g; auxiliary preparation equipment is selected separately.
TS EN ISO 105-D01:2011 · 6.1, 8
- Dry-cleaning recipe: 550 ± 50 mL vessel with solvent-resistant seals, 40 ± 2 r/min and 30 ± 2 °C. Solvent and required fume hood are assessed separately from the aqueous-washing configuration.
AATCC 61-2009 · 5.1.1-5.1.5
- Rotation 40 ± 2 r/min; vessels differ: 500 mL (75 × 125 mm) for 1A and 1200 mL (90 × 200 mm) for 1B/2A/3A/4A/5A. Steel-ball diameter 6 mm; vessel and abrasive set are recorded for the selected test number.
TS EN ISO 105-C10:2011 · 4.1-4.4
- Vessel 550 ± 50 mL, diameter 75 ± 5 mm, height 125 ± 10 mm; rotation 40 ± 2 r/min and solution within ±2 °C of the selected temperature. Approximately 6 mm steel balls and soap/alkali recipe recorded for the selected test condition.
TS EN ISO 105-E03:2010 · 4.1
- Chlorinated-water fastness arrangement: glass or stainless 550 ± 50 mL vessel, 40 ± 2 r/min and ±2 °C solution-temperature control. Active-chlorine level and solution pH are tracked in separate recipe fields.
M&S C37:2006-02 · Apparatus
- Chlorinated-water fastness: 500 ± 50 mL vessel, chlorine-resistant seal, 27 ± 2 °C and 40 ± 2 r/min. This edition excludes infrared-heated wash wheels.
M&S C10A — June 2007 · Apparatus 1–3; Specimen; Wash liquor; Method 1–8; Note5; pp.1–4
- M&S C10A June 2007: vessel capacity 550 ± 50 mL, rotation 40 ± 2 rpm; infrared-heated wash wheels are not accepted in this edition. These historical method requirements do not automatically apply to sample-dyeing machines. The auxiliary stirrer must sustain about 1000 rpm for at least 10 min; balance accuracy at least ±0.01 g.
- Fabric specimen 100 × 40 mm; liquor ratio 100:1 (100 mL solution per 1 g fabric). Start at 27 ± 2 °C and ramp at 1.5 ± 0.5 °C/min. A 40 °C care label uses a 50 °C test; a 50 °C label uses 60 °C. Start the 30 min hold on reaching the target. These method volumes/specimen masses are not machine capacity or net weight.
- The method assesses oxidative-bleach colour change; no multifibre adjacent fabric or staining assessment. Prepare fresh solution for immediate use and adjust TAED mass to documented activity. Drying limit 60 °C. Current M&S approval and delivered ramp accuracy require separate verification.
Control and recording specification
The following are method-specific software/recording requirements; delivered software modules are defined by the order scope.
- Method code and edition, specimen ID, operator and selected test parameters are linked to the record.
- The calculation and endpoint are defined by the selected method edition; instrument signals and operator assessments are kept distinct.
- Raw measurements, units, valid/invalid test flags and the reported result remain traceable.
- Calculations are checked against known inputs and an independent calculation; sensor channels are checked against calibration values.
- The C10A record links care-label/test temperatures, measured ramp and a 30 min hold starting at target temperature. Trace specimen mass/liquor volume and reagent activity; do not add optical-brightener effects or multifibre staining scores to this result. These are method requirements; delivered modules are specified separately.
Test standards
- AATCC 61 Test Method for Colorfastness to Laundering: Accelerated
- ISO 105-C06 Textiles — Tests for colour fastness — Part C06: Colour fastness to domestic and commercial laundering
- ISO 105-C08 Textiles — Tests for colour fastness — Part C08: Colour fastness to domestic and commercial laundering using a non-phosphate reference detergent incorporating a low-temperature bleach activator
- ISO 105-C09 Textiles — Tests for colour fastness — Part C09: Colour fastness to domestic and commercial laundering — Oxidative bleach response using a non-phosphate reference detergent incorporating a low temperature bleach activator
- ISO 105-C10 Textiles — Tests for colour fastness — Part C10: Colour fastness to washing with soap or soap and soda
- ISO 105-D01 Textiles — Tests for colour fastness — Part D01: Colour fastness to drycleaning using perchloroethylene solvent
- ISO 105-E03 Textiles — Tests for colour fastness — Part E03: Colour fastness to chlorinated water (swimming-pool water)
- M&S C04
- M&S C05
- M&S C10A
- M&S C12A
- M&S C37
- JIS L 0844 Test methods for colour fastness to washing and laundering
- GB/T 5711 Textiles — Tests for colour fastness — Colour fastness to drycleaning using perchloroethylene solvent
- GB/T 3921 Textiles — Tests for colour fastness — Colour fastness to washing with soap or soap and soda
- JIS L 0860 Test methods for colour fastness to dry cleaning
- AATCC 132 Test Method for Colorfastness to Drycleaning
- AATCC 86 Test Method for Drycleaning: Durability of Applied Designs and Finishes
- GB/T 12490 Textiles — Tests for colour fastness — Colour fastness to domestic and commercial laundering
- M&S C4A
- NEXT TM 2
- AATCC 190 Colorfastness to Home Laundering with Activated Oxygen Bleach Detergent: Accelerated
- ISO 105-E12 Textiles — Tests for colour fastness — Part E12: Colour fastness to milling: Alkaline milling
- ISO 105-C01 Textiles — Tests for colour fastness — Part C01: Colour fastness to washing: Test 1
- ISO 105-C05 Textiles — Tests for colour fastness — Part C05: Colour fastness to washing: Test 5
Prices start from €18. Request the technical specification and a quotation for this instrument.
Request a quoteCall usPDF catalogueMore in this category

Infrared Sample Dyeing Machine

Sample Dyeing Machine (Oil-Bath)

Laboratory Package and Fibre Dyeing Machine

Drum-Type Piece Fabric Dyeing Machine
Related application guides
Laboratory guides related to this topic:
Articles about this instrument
Other instruments in this group
- TXL-BOY-002Infrared Sample Dyeing Machine
- TXL-BOY-003Sample Dyeing Machine (Oil-Bath)
- TXL-BOY-004Laboratory Package and Fibre Dyeing Machine
- TXL-BOY-005Drum-Type Piece Fabric Dyeing Machine
- TXL-BOY-006Foulard / Padding Mangle
- TXL-BOY-007Mini Stenter (Laboratory Dryer)
- TXL-BOY-013Temperature Indicator Strips
- TXL-BOY-014Horizontal Padder
- TXL-BOY-016Laboratory Reference Washing Machine (ISO 6330)
- TXL-BOY-017Laboratory Coating Knife (RKL 40)
- TXL-BOY-018AATCC Shrinkage Washing Machine (Top-Loading)
- TXL-BOY-019AATCC Shrinkage Tumble Dryer