Foulard / Padding Mangle
Fular (Pnömatik Sıkma Makinesi)
Laboratory pneumatic padding mangle for impregnation.
Model technical data
- Horizontally mounted rollers, 350 mm wide.
- Fabric pass-through speed: 0-15 m/min.
- Roller squeezing pressure adjustable between 0 and 6 bar.
Physical specifications and utilities
| Electrical supply | Approx. 220–240 V AC, 50/60 Hz, single phase; build-dependent. |
|---|---|
| Power / connected load | Approx. 400–1000 W connected load for preliminary planning. |
| Overall instrument dimensions | Approx. 1000 × 650 × 800 mm (W × D × H). |
| Instrument weight | Approx. 120–220 kg net. |
| Gross / shipping weight | Approx. 157–300 kg gross; estimated packing allowance. |
| Lab requirements | Dry filtered compressed air if the pneumatic circuit is fitted; operating pressure and flow confirmed at delivery. |
Dimension order and approximate values are stated in each row. Packaging data are separate from instrument dimensions and net mass. Approx. rows are preliminary engineering estimates based on comparable equipment and function/capacity; they are not verified manufacturing measurements or standard requirements. Installation and shipment are finalised against the approved drawing and nameplate. Estimate scope: base product / one unit; external computer, bench and auxiliary plant excluded.
Specifications, dimensions, and power requirements are approximate and subject to change without prior notice for continuous design improvements.
Product technical specifications and images may vary according to manufacturing conditions and applicable standards.
Test and configuration
- Measured output / function
- Wet pick-up after impregnation and squeezing (%)
- Parameters selected for the method
- Roller pressure, feed speed and fabric width
- Verification points
- Roller parallelism, pressure and speed
Listed methods are application references. Suitability is established by assessing the selected hardware, current method and calibration together.
Control and recording specification
The following are method-specific software/recording requirements; delivered software modules are defined by the order scope.
- Method code and edition, specimen ID, operator and selected test parameters are linked to the record.
- The calculation and endpoint are defined by the selected method edition; instrument signals and operator assessments are kept distinct.
- Raw measurements, units, valid/invalid test flags and the reported result remain traceable.
- Calculations are checked against known inputs and an independent calculation; sensor channels are checked against calibration values.
Prices start from €18. Request the technical specification and a quotation for this instrument.