Photographs have been adapted for the website; dimensions may vary.
Sample Dyeing Machine (Oil-Bath)
Numune Boyama Makinesi (Yağlı Sistem)
High-temperature sample dyeing with oil-bath heating.
Model technical data
- Ten 300 cc stainless steel (AISI 316) dyeing tubes.
- Thermal oil circulation heating system for homogeneous temperature distribution.
- 3.5" touch screen control unit: 99 programmes with 20 steps each.
- Safety thermostat and over-temperature protection system.
- Capable of both atmospheric and polyester (HT) dyeing.
- Compact benchtop design.
- Standard equipment: tube carrying basket and tube lid gasket sets.
Physical specifications and utilities
| Electrical supply | Approx. 220–240 V AC, 50/60 Hz, single phase; build-dependent. |
|---|---|
| Power / connected load | Approx. 2000–3500 W connected load for preliminary planning. |
| Overall instrument dimensions | Approx. 750 × 650 × 650 mm (W × D × H). |
| Instrument weight | Approx. 55–90 kg net. |
| Gross / shipping weight | Approx. 85.5–137.5 kg gross; estimated packing allowance. |
| Lab requirements | Heat-resistant bench and ventilation; clearance for hot surfaces. |
Dimension order and approximate values are stated in each row. Packaging data are separate from instrument dimensions and net mass. Approx. rows are preliminary engineering estimates based on comparable equipment and function/capacity; they are not verified manufacturing measurements or standard requirements. Installation and shipment are finalised against the approved drawing and nameplate. Estimate scope: base product / one unit; external computer, bench and auxiliary plant excluded.
Specifications, dimensions, and power requirements are approximate and subject to change without prior notice for continuous design improvements.
Product technical specifications and images may vary according to manufacturing conditions and applicable standards.
Test and configuration
- Measured output / function
- Laboratory dyeing and recipe comparison
- Parameters selected for the method
- Sample load, liquor ratio and temperature-time profile
- Verification points
- Temperature sensor and programme durations
Listed methods are application references. Suitability is established by assessing the selected hardware, current method and calibration together.
Control and recording specification
The following are method-specific software/recording requirements; delivered software modules are defined by the order scope.
- Method code and edition, specimen ID, operator and selected test parameters are linked to the record.
- The calculation and endpoint are defined by the selected method edition; instrument signals and operator assessments are kept distinct.
- Raw measurements, units, valid/invalid test flags and the reported result remain traceable.
- Calculations are checked against known inputs and an independent calculation; sensor channels are checked against calibration values.
Prices start from €18. Request the technical specification and a quotation for this instrument.
Request a quoteCall usPDF catalogue