Mini Stenter (Laboratory Dryer)
Laboratuvar Tipi Ramöz (Mini Ram)
Dries and fixes fabric samples under tension after dyeing and washing. Temperature 25–250 °C, heating rate 15 °C/min, adjustable air circulation 850–1,700 m³/h; temperature and time programmable on a touch-panel PLC. Maximum sample size 350 × 350 mm; pin and adjustable frame options, automatic sample release at the end of the process.
Model technical data
- Working temperature: 25–250 °C.
- Heating capacity: 4,500 W; heating rate 15 °C/min.
- Air circulation: 850–1,700 m³/h, adjustable.
- Touch-panel PLC; programmable temperature and time.
- Interface: RS232.
- Maximum sample size: 350 × 350 mm; pin and adjustable frame models.
- The sample is released automatically at the end of the process.
Physical specifications and utilities
| Electrical supply | Approx. 380–415 V AC, 50 Hz, three phase; 60 Hz is a separate build option. |
|---|---|
| Power / connected load | Manufacturer data: heater 4500 W; not the total connected load. Approx. 5000–6500 W connected load for preliminary planning. |
| Overall instrument dimensions | Approx. 1400 × 800 × 900 mm (W × D × H). |
| Instrument weight | Approx. 150–220 kg net. |
| Gross / shipping weight | Approx. 190–300 kg gross; estimated packing allowance. |
| Interfaces | Interface: RS232. |
| Lab requirements | Suitable ventilation / process exhaust; external fan and duct loads are excluded from this preliminary estimate. |
Dimension order and approximate values are stated in each row. Packaging data are separate from instrument dimensions and net mass. Approx. rows are preliminary engineering estimates based on comparable equipment and function/capacity; they are not verified manufacturing measurements or standard requirements. Installation and shipment are finalised against the approved drawing and nameplate. Estimate scope: base product / one unit; external computer, bench and auxiliary plant excluded.
Specifications, dimensions, and power requirements are approximate and subject to change without prior notice for continuous design improvements.
Product technical specifications and images may vary according to manufacturing conditions and applicable standards.
Test and configuration
- Measured output / function
- Drying, steaming and heat setting
- Parameters selected for the method
- Specimen frame, temperature, duration and airflow
- Verification points
- Temperature distribution in the working area and timing
Listed methods are application references. Suitability is established by assessing the selected hardware, current method and calibration together.
Control and recording specification
The following are method-specific software/recording requirements; delivered software modules are defined by the order scope.
- Method code and edition, specimen ID, operator and selected test parameters are linked to the record.
- The calculation and endpoint are defined by the selected method edition; instrument signals and operator assessments are kept distinct.
- Raw measurements, units, valid/invalid test flags and the reported result remain traceable.
- Calculations are checked against known inputs and an independent calculation; sensor channels are checked against calibration values.
Prices start from €18. Request the technical specification and a quotation for this instrument.
Request a quoteCall usPDF catalogue