
Photographs have been adapted for the website; dimensions may vary.
Sling Psychrometer
Savurmalı Tip Nem Ölçer
Relative humidity measurement by rotation. Instantly and accurately detects moisture and temperature controls, which are critically important for sensitive production environments. Offers portable and practical use.
Model technical data
- Whirling psychrometer for ambient temperature and relative humidity.
- Assessment using wet- and dry-bulb temperatures.
- Supplied as a set with a relative-humidity table.
- Measurement range and thermometer resolution are specified for the selected model.
Physical specifications and utilities
| Electrical supply | Manual / passive base apparatus; no mains supply assumed. |
|---|---|
| Power / connected load | Approx. 0 W connected load for preliminary planning. |
| Overall instrument dimensions | Approx. 300 × 100 × 50 mm (W × D × H). |
| Instrument weight | Approx. 0.1–0.3 kg net. |
| Gross / shipping weight | Approx. 0.5–0.8 kg gross; estimated packing allowance. |
| Lab requirements | Level, stable working surface; specimen conditioning follows the selected method. |
Dimension order and approximate values are stated in each row. Packaging data are separate from instrument dimensions and net mass. Approx. rows are preliminary engineering estimates based on comparable equipment and function/capacity; they are not verified manufacturing measurements or standard requirements. Installation and shipment are finalised against the approved drawing and nameplate. Estimate scope: base product / one unit; external computer, bench and auxiliary plant excluded.
Specifications, dimensions, and power requirements are approximate and subject to change without prior notice for continuous design improvements.
Product technical specifications and images may vary according to manufacturing conditions and applicable standards.
Test and configuration
- Measured output / function
- Ambient temperature and relative humidity (%RH)
- Parameters selected for the method
- Placement, measurement interval and measuring method
- Verification points
- Temperature and relative humidity references
Listed methods are application references. Suitability is established by assessing the selected hardware, current method and calibration together.
Test parameters for the reviewed method
Values belong to the stated source edition. Test recipe, fixture and delivered instrument configuration are selected together.
ISO 139:2005 + Amd 1:2011 · 3-5, Annex A
- Standard atmosphere 20 °C / 65% RH; agreed alternatives 23 °C / 50% RH or 27 °C / 65% RH, tolerances ±2 °C and ±4% RH. Recommended monitor resolution 0.1 °C and 0.1% RH or better; measurement uncertainty ±0.5 °C and ±2% RH or better. Assess monitoring sensors separately from control sensors.
Control and recording specification
The following are method-specific software/recording requirements; delivered software modules are defined by the order scope.
- The need for integrated software depends on the method and selected hardware; manual instruments use an external test record.
- Method code and edition, specimen ID, operator and selected test parameters are linked to the record.
- The calculation and endpoint are defined by the selected method edition; instrument signals and operator assessments are kept distinct.
- Raw measurements, units, valid/invalid test flags and the reported result remain traceable.
- Calculations are checked against known inputs and an independent calculation; sensor channels are checked against calibration values.
Test standards
Prices start from €18. Request the technical specification and a quotation for this instrument.
Request a quoteCall usPDF catalogue


