Catalogue › Washing Fastness & Lab Dyeing Machines › Laboratory Steamer / Steam Cabinet
Laboratory Steamer / Steam Cabinet

Photographs have been adapted for the website; dimensions may vary.

TXL-BOY-009

Laboratory Steamer / Steam Cabinet

Laboratuvar Buharlayıcı

Fixation and steaming cabinet with saturated steam.

Model technical data

  • Maximum temperature is 250 C°; maximum sample diameter is 350 mm x 350 mm.
  • Interior cabin is made of stainless steel.

Physical specifications and utilities

Electrical supplyApprox. 380–415 V AC, 50 Hz, three phase; 60 Hz is a separate build option.
Power / connected loadApprox. 6000–12000 W connected load for preliminary planning.
Overall instrument dimensionsApprox. 900 × 850 × 1600 mm (W × D × H).
Instrument weightApprox. 150–250 kg net.
Gross / shipping weightApprox. 190–337.5 kg gross; estimated packing allowance.
Lab requirementsSuitable water feed, drain and steam exhaust; external steam depends on generator option.

Dimension order and approximate values are stated in each row. Packaging data are separate from instrument dimensions and net mass. Approx. rows are preliminary engineering estimates based on comparable equipment and function/capacity; they are not verified manufacturing measurements or standard requirements. Installation and shipment are finalised against the approved drawing and nameplate. Estimate scope: base product / one unit; external computer, bench and auxiliary plant excluded.

Specifications, dimensions, and power requirements are approximate and subject to change without prior notice for continuous design improvements.

Product technical specifications and images may vary according to manufacturing conditions and applicable standards.

Test and configuration

Measured output / function
Drying, steaming and heat setting
Parameters selected for the method
Specimen frame, temperature, duration and airflow
Verification points
Temperature distribution in the working area and timing

Listed methods are application references. Suitability is established by assessing the selected hardware, current method and calibration together.

Control and recording specification

The following are method-specific software/recording requirements; delivered software modules are defined by the order scope.

  • Method code and edition, specimen ID, operator and selected test parameters are linked to the record.
  • The calculation and endpoint are defined by the selected method edition; instrument signals and operator assessments are kept distinct.
  • Raw measurements, units, valid/invalid test flags and the reported result remain traceable.
  • Calculations are checked against known inputs and an independent calculation; sensor channels are checked against calibration values.
Download the technical brochure (PDF)Revision: 27 October 2026

Prices start from €18. Request the technical specification and a quotation for this instrument.

Request a quoteCall usPDF catalogue

More in this category

Washing Fastness Tester (Gyrowash)
TXL-BOY-001

Washing Fastness Tester (Gyrowash)

Infrared Sample Dyeing Machine
TXL-BOY-002

Infrared Sample Dyeing Machine

Sample Dyeing Machine (Oil-Bath)
TXL-BOY-003

Sample Dyeing Machine (Oil-Bath)

Package Dyeing Machine (Lab)
TXL-BOY-004

Package Dyeing Machine (Lab)