Cabinet for controlled flame contact and measurement of flame-spread time in blanket textiles. Verify flame-application control and spread timer separately.

Model technical data

  • Many different test methods can be installed help with touch screen control unit and computer connection.

Physical specifications and utilities

Electrical supplyApprox. 220–240 V AC, 50/60 Hz, single phase; build-dependent.
Power / connected loadApprox. 20–100 W connected load for preliminary planning.
Overall instrument dimensionsApprox. 1000 × 800 × 1300 mm (W × D × H).
Instrument weightApprox. 50–90 kg net.
Gross / shipping weightApprox. 80–137.5 kg gross; estimated packing allowance.
Lab requirementsMethod-specified test gas, regulator and exhaust / fume hood; gas type and flow follow the selected method and burner.

Dimension order and approximate values are stated in each row. Packaging data are separate from instrument dimensions and net mass. Approx. rows are preliminary engineering estimates based on comparable equipment and function/capacity; they are not verified manufacturing measurements or standard requirements. Installation and shipment are finalised against the approved drawing and nameplate. Estimate scope: base product / one unit; external computer, bench and auxiliary plant excluded.

Specifications, dimensions, and power requirements are approximate and subject to change without prior notice for continuous design improvements.

Product technical specifications and images may vary according to manufacturing conditions and applicable standards.

Test and configuration

Measured output / function
Burning behaviour of blanket specimens
Parameters selected for the method
Specimen orientation, flame application and conditioning
Verification points
Burner/gas flow, geometry and timing

Listed methods are application references. Suitability is established by assessing the selected hardware, current method and calibration together.

Test parameters for the reviewed method

Values belong to the stated source edition. Test recipe, fixture and delivered instrument configuration are selected together.

ASTM D4151-92 (2001) · 6.1–6.1.1.2

  • Control flame contact in the blanket cabinet to 1 ±0.05 seconds. The flame-spread counter reads to 0.01 seconds; counter resolution is distinct from flame-contact timing accuracy. Verify both timing functions separately.

Control and recording specification

The following are method-specific software/recording requirements; delivered software modules are defined by the order scope.

  • Method code and edition, specimen ID, operator and selected test parameters are linked to the record.
  • The calculation and endpoint are defined by the selected method edition; instrument signals and operator assessments are kept distinct.
  • Raw measurements, units, valid/invalid test flags and the reported result remain traceable.
  • Calculations are checked against known inputs and an independent calculation; sensor channels are checked against calibration values.
Download the technical brochure (PDF)Revision: 27 October 2026

Test standards

Prices start from €18. Request the technical specification and a quotation for this instrument.

Request a quoteCall usPDF catalogue

More in this category

Vertical Flame Spread Tester
TXL-YAN-001

Vertical Flame Spread Tester

45° Flammability Tester
TXL-YAN-002

45° Flammability Tester

Horizontal Flammability Tester
TXL-YAN-003

Horizontal Flammability Tester

NFPA 701 Flame Propagation Tester
TXL-YAN-004

NFPA 701 Flame Propagation Tester