Catalogue › General Laboratory Equipment › Conditioning Air Unit (Room Type)
Conditioning Air Unit (Room Type)

Photographs have been adapted for the website; dimensions may vary.

TXL-GEN-016

Conditioning Air Unit (Room Type)

İklimlendirme Ünitesi (Oda Tipi)

Temperature and humidity controlled room-type conditioning unit that provides a standards-compliant test environment for industry, R&D, university, medical and textile laboratories. Available in different volume capacities; request the technical datasheet for the capacity you need.

Model technical data

  • Provides temperature and humidity controlled conditioning for industry, R&D, university, medical and textile laboratories.

Physical specifications and utilities

Electrical supplyApprox. 380–415 V AC, 50 Hz, three phase; 60 Hz is a separate build option.
Power / connected loadApprox. 5000–20000 W connected load for preliminary planning.
Overall instrument dimensionsApprox. 1200 × 900 × 1800 mm (W × D × H).
Instrument weightApprox. 200–500 kg net.
Gross / shipping weightApprox. 245–650 kg gross; estimated packing allowance.
Lab requirementsRoom volume, heat/moisture loads, ducts and water/drain are project-sized. This estimate is for a representative air-handling unit only, not the total room system.

Dimension order and approximate values are stated in each row. Packaging data are separate from instrument dimensions and net mass. Approx. rows are preliminary engineering estimates based on comparable equipment and function/capacity; they are not verified manufacturing measurements or standard requirements. Installation and shipment are finalised against the approved drawing and nameplate. Estimate scope: base product / one unit; external computer, bench and auxiliary plant excluded.

Specifications, dimensions, and power requirements are approximate and subject to change without prior notice for continuous design improvements.

Product technical specifications and images may vary according to manufacturing conditions and applicable standards.

Test and configuration

Measured output / function
Specimen conditioning at controlled temperature and relative humidity
Parameters selected for the method
Target temperature, relative humidity, load and conditioning time
Verification points
Temperature-humidity mapping and temporal stability

Listed methods are application references. Suitability is established by assessing the selected hardware, current method and calibration together.

Control and recording specification

The following are method-specific software/recording requirements; delivered software modules are defined by the order scope.

  • Method code and edition, specimen ID, operator and selected test parameters are linked to the record.
  • The calculation and endpoint are defined by the selected method edition; instrument signals and operator assessments are kept distinct.
  • Raw measurements, units, valid/invalid test flags and the reported result remain traceable.
  • Calculations are checked against known inputs and an independent calculation; sensor channels are checked against calibration values.
Download the technical brochure (PDF)Revision: 27 October 2026

Prices start from €18. Request the technical specification and a quotation for this instrument.

Request a quoteCall usPDF catalogue

More in this category

Light Assessment Cabinet (D65/TL84/UV/A)
TXL-GEN-001

Light Assessment Cabinet (D65/TL84/UV/A)

UV Weathering / Ageing Tester
TXL-GEN-002

UV Weathering / Ageing Tester

Laboratory Drying Oven
TXL-GEN-003

Laboratory Drying Oven

Orbital Shaker
TXL-GEN-004

Orbital Shaker