Catalogue › Footwear & Leather Testing › Sand Bath
Sand Bath

Photographs have been adapted for the website; dimensions may vary.

TXL-DER-004

Sand Bath

Kum Banyosu

Used in research, food, pharmaceutical, chemical and automotive laboratories. Heats from 50 °C up to 300 °C; the heaters are embedded in the body for fast warm-up. Insulated against heat loss with reflectors and controlled by a digital thermostat.

Model technical data

  • Used in research, food, pharmaceutical, chemical and automotive laboratories.
  • Heats from 50 °C up to 300 °C.
  • The heaters are embedded in the body, providing fast warm-up.
  • Insulated against heat loss with reflectors.
  • Temperature is controlled by a digital thermostat.

Physical specifications and utilities

Electrical supplyApprox. 220–240 V AC, 50/60 Hz, single phase; build-dependent.
Power / connected loadApprox. 1000–2500 W connected load for preliminary planning.
Overall instrument dimensionsApprox. 600 × 500 × 400 mm (W × D × H).
Instrument weightApprox. 15–35 kg net.
Gross / shipping weightApprox. 26.5–53.8 kg gross; estimated packing allowance.
Lab requirementsHeat-resistant bench and ventilation; clearance for hot surfaces.

Dimension order and approximate values are stated in each row. Packaging data are separate from instrument dimensions and net mass. Approx. rows are preliminary engineering estimates based on comparable equipment and function/capacity; they are not verified manufacturing measurements or standard requirements. Installation and shipment are finalised against the approved drawing and nameplate. Estimate scope: base product / one unit; external computer, bench and auxiliary plant excluded.

Specifications, dimensions, and power requirements are approximate and subject to change without prior notice for continuous design improvements.

Product technical specifications and images may vary according to manufacturing conditions and applicable standards.

Test and configuration

Measured output / function
Solution preparation, mixing or controlled heating
Parameters selected for the method
Selection of volume, vessel, speed, temperature and time
Verification points
Speed and temperature control where applicable

Listed methods are application references. Suitability is established by assessing the selected hardware, current method and calibration together.

Control and recording specification

The following are method-specific software/recording requirements; delivered software modules are defined by the order scope.

  • Method code and edition, specimen ID, operator and selected test parameters are linked to the record.
  • The calculation and endpoint are defined by the selected method edition; instrument signals and operator assessments are kept distinct.
  • Raw measurements, units, valid/invalid test flags and the reported result remain traceable.
  • Calculations are checked against known inputs and an independent calculation; sensor channels are checked against calibration values.
Download the technical brochure (PDF)Revision: 27 October 2026

Prices start from €18. Request the technical specification and a quotation for this instrument.

Request a quoteCall usPDF catalogue

More in this category

Elastomer Sole Abrasion Tester
TXL-DER-001

Elastomer Sole Abrasion Tester

Leather Rub Fastness Tester
TXL-DER-002

Leather Rub Fastness Tester

Flexometer — Cold Environment Tester
TXL-DER-003

Flexometer — Cold Environment Tester