Catalogue › Footwear & Leather Testing › Flexometer — Cold Environment Tester
Flexometer — Cold Environment Tester

Photographs have been adapted for the website; dimensions may vary.

TXL-DER-003

Flexometer — Cold Environment Tester

Fleksometre — Soğuk Ortam Test Cihazı

Detects the resistance of coating layers on the leather surface during continuous folding and flexing. Twelve leather specimens can be tested simultaneously. Test parameters can be changed as required from the control unit; tests can be run down to −25 °C.

Model technical data

  • Detects the resistance of coating layers on the leather surface to continuous folding and flexing.
  • Twelve leather specimens can be tested simultaneously.
  • Tests can be carried out down to −25 °C.

Physical specifications and utilities

Electrical supplyApprox. 220–240 V AC, 50/60 Hz, single phase; build-dependent.
Power / connected loadApprox. 1500–3000 W connected load for preliminary planning.
Overall instrument dimensionsApprox. 850 × 750 × 1300 mm (W × D × H).
Instrument weightApprox. 100–180 kg net.
Gross / shipping weightApprox. 135–250 kg gross; estimated packing allowance.
Lab requirementsVentilated installation; purified water and drain for humidification options. Separate conditioning plant depends on order scope.

Dimension order and approximate values are stated in each row. Packaging data are separate from instrument dimensions and net mass. Approx. rows are preliminary engineering estimates based on comparable equipment and function/capacity; they are not verified manufacturing measurements or standard requirements. Installation and shipment are finalised against the approved drawing and nameplate. Estimate scope: base product / one unit; external computer, bench and auxiliary plant excluded.

Specifications, dimensions, and power requirements are approximate and subject to change without prior notice for continuous design improvements.

Product technical specifications and images may vary according to manufacturing conditions and applicable standards.

Test and configuration

Measured output / function
Leather surface damage after repeated flexing
Parameters selected for the method
Specimen direction, temperature, flexing and cycles
Verification points
Temperature, counter and holder motion

Listed methods are application references. Suitability is established by assessing the selected hardware, current method and calibration together.

Control and recording specification

The following are method-specific software/recording requirements; delivered software modules are defined by the order scope.

  • Method code and edition, specimen ID, operator and selected test parameters are linked to the record.
  • The calculation and endpoint are defined by the selected method edition; instrument signals and operator assessments are kept distinct.
  • Raw measurements, units, valid/invalid test flags and the reported result remain traceable.
  • Calculations are checked against known inputs and an independent calculation; sensor channels are checked against calibration values.
  • Select DIN 53351 edition and material scope explicitly: the accessed 1983 cover/page 1 covers leather, artificial leather and similar sheets; the 2003 title covers artificial leather and similar sheets. The 1983 first page omits apparatus figures on pages 2–4. The model’s −25 °C capability is not a standard test temperature; holder, folding movement and recipe suitability require separate verification.

Historical method references (current method and fixture require separate review): DIN 53351

Download the technical brochure (PDF)Revision: 27 October 2026

Test standards

Prices start from €18. Request the technical specification and a quotation for this instrument.

Request a quoteCall usPDF catalogue

More in this category

Elastomer Sole Abrasion Tester
TXL-DER-001

Elastomer Sole Abrasion Tester

Leather Rub Fastness Tester
TXL-DER-002

Leather Rub Fastness Tester

Sand Bath
TXL-DER-004

Sand Bath