TEST METHOD

Pilling tests compared: ICI pilling box (ISO 12945-1), Martindale (ISO 12945-2) and random tumble (ASTM D3512)

November 24, 2026 · 6 min read

Pilling is the formation of small balls of tangled fibre on a fabric surface. No laboratory test reproduces wear exactly, so standards create pills mechanically and then grade the result visually from 5 (no change) to 1 (severe pilling). The three common methods do this in different ways, and their grades are not interchangeable.

The three methods at a glance

Values below are from the editions we checked: EN ISO 12945-1:2000, EN ISO 12945-2:2000 and ASTM D3512-02. All three have been revised since, so check the current text before writing a procedure.

ICI pilling box (ISO 12945-1)Martindale (ISO 12945-2)Random tumble (ASTM D3512)
How pills formSpecimens mounted on tubes tumble in a cork-lined boxSpecimen rubs against fabric or a wool abradant along a Lissajous pathSpecimens tumble freely in a cork-lined chamber driven by an impeller, with air injection
Key apparatusBox 235 mm inside, 3.2 mm cork lining, 60 ± 2 rpm; four polyurethane tubes 140 mm longHolder 155 ± 1 g; with the extra disc 415 ± 2 g1.5 mm cork liners; 14–21 kPa air; about 25 mg of grey cotton fibre added
SpecimensFour 125 × 125 mm, sewn into tubes (two lengthwise, two widthwise)Circular specimens and matching abradant; at least three pairsThree 105 mm squares cut at 45° (bias), edges sealed
Test lengthNumber of revolutions agreed between the partiesAssessed at stages: 125, 500, 1 000, 2 000, 5 000, 7 000 rubs (woven and knitted)30 min unless otherwise agreed
Grade5 to 1, half grades allowed5 to 1 at each stage, half grades allowed5 to 1 against fabric or photographic standards

ICI pilling box

The box method is simple and gentle. Its main open point is test length: ISO 12945-1 states that no single number of revolutions suits every fabric, so the number must be agreed and reported. A grade 4 after one revolution count and a grade 4 after another are different results. The cork lining must be inspected regularly and replaced when it is damaged or contaminated, because it is the rubbing surface. Specimens are conditioned for at least 16 h in the ISO 139 atmosphere before testing.

Martindale

The modified Martindale method rubs the specimen in a Lissajous figure, which changes direction continuously. ISO 12945-2 sets categories in its Annex A:

CategoryAbradantLoadAssessment stages (rubs)
1 UpholsteryWool abradant fabric415 ± 2 g500 · 1 000 · 2 000 · 5 000
2 Woven (not upholstery)Same fabric face to face, or wool415 ± 2 g125 · 500 · 1 000 · 2 000 · 5 000 · 7 000
3 Knitted (not upholstery)Same fabric face to face, or wool155 ± 1 g125 · 500 · 1 000 · 2 000 · 5 000 · 7 000

For categories 2 and 3 the minimum is 2 000 rubs. Because the grade is recorded at each stage, a Martindale result shows how pilling develops and, for some fibres, how pills wear off again. The report must state the abradant, the load and the number of rubs at each stage. For more detail see our note on why two laboratories grade Martindale pilling differently.

Random tumble

In ASTM D3512, three bias-cut specimens tumble in a cork-lined chamber with a small amount of grey cotton fibre, which helps pills form with an appearance closer to worn garments. The cork liners matter: each face is discarded after 1 h of use, and the tester should be checked with an in-house reference fabric at least once a week when in constant use, and whenever a new shipment of liners arrives. ISO 12945-3 is the ISO random-tumble method; check it separately if your specification calls for it.

ASTM D3512 also gives a useful warning about precision: in its interlaboratory study, fabrics averaging 2.0 or below, or 4.0 or above, showed high agreement between laboratories, while fabrics between 2.0 and 4.0 showed low agreement. Mid-range grades are where disputes happen.

Which method should you use?

Never convert a grade from one method to another. Report the method, edition, revolutions, rubs or running time, abradant, pre-treatment such as washing, and the number of observers.

Grading is the weak point

All three methods rely on visual assessment. ISO 12945-1 specifies the viewing set-up: light at 5° to 15° to the specimen plane, and a viewing distance of 30 to 50 cm. It also recommends more than one observer. Use the same viewing cabinet and the same photographic or fabric standards every time.

Frequently asked questions

Is a grade 4 on the box the same as a grade 4 on Martindale?

No. The mechanisms and test lengths differ, so the grades are not comparable.

How many revolutions should I run on the ICI box?

ISO 12945-1 leaves this to agreement between the parties. Use the number in your customer's specification and report it.

Why add cotton fibre in the random tumble test?

ASTM D3512 adds a small amount of short grey cotton fibre so that pills form with an appearance and structure closer to those produced in actual wear.

Cenk YILMAZ
TLI-TexLabInstruments

TLI instruments for this test

Need the right instrument to run this test in your lab? Let us help you choose.

Request a quote

Standards referred to in this guide